Technical Article
Chiller and AHU Maintenance Checklist: What to Watch, Record and Plan
10 November 2026 · 3 min read
A practical chiller and AHU maintenance checklist for facility teams — routine observations, planned maintenance and records, plus what chiller and HVAC firms should explain clearly on their websites.
A chiller and AHU maintenance checklist should help your team spot changes early, keep useful records and plan servicing — not replace the instructions from the manufacturer or the work of qualified technicians.
At Chivico Engineering I carried out repair and maintenance on a Trane chiller, including compressor replacement, and installed and commissioned an AHU serving that chiller. I also worked on the installation, commissioning and start-up of two York YVAA air-cooled VSD screw chillers complete with condenser fans, and attended York YVAA chiller training with Johnson Controls in Dubai, UAE in 2019.
That background shapes how I write about cooling services: make the technical work understandable without disguising its complexity.
## How to use this checklist
- Work at the intervals in the operating procedures for your site and the requirements from the equipment manufacturer. There is no single schedule that suits every chiller, AHU or building. - Record what you find, even when everything is normal. A trend across weeks tells you more than one good reading. - Treat anything outside approved limits as a reason to involve the responsible qualified person, not to improvise.
## Routine operating checks
Use these prompts at the intervals in the procedures for your site, from safe observation points:
- **Readings:** Log chiller leaving and returning water temperatures, pressures and currents against the values your site approved and against previous entries. - **Air side:** Note airflow changes, filter condition, coil fouling and unusual noise or vibration at the AHU and its fans. - **Water side:** Watch for pressure drops, flow changes, unusual temperatures or signs of leaks at pumps, valves and connections. - **Controls and alarms:** Record alarms, repeated faults and manual overrides. Do not bypass protective controls to keep cooling running. - **Environment:** Note debris, stored items or blocked access around condensers, condensate lines and air intakes. - **Handover:** Log what changed, who was informed and what action is still outstanding.
If readings fall outside approved limits or a protective control trips, follow the emergency procedure for your site and involve the responsible qualified person.
## Planned maintenance checks
During scheduled maintenance, ask your service provider to address the items relevant to your equipment:
- **Refrigerant circuit:** Leak checks and any required servicing, carried out by technicians qualified for refrigerant work under the rules that apply at your site. - **Electrical:** Connections, protection and control wiring, with the supply isolated and the work done by qualified electrical personnel. - **Compressors and motors:** Condition, sound, vibration and lubrication as specified by the manufacturer. - **Coils, filters and condensate:** Cleaning of coils and drain pans, filter replacement, and confirmation that condensate drains freely. - **Water treatment:** Treatment results assessed against the programme, with deposits or corrosion noted at heat-exchange surfaces. - **Controls and sensors:** Calibration checks, setpoint verification and confirmation that safety controls respond as intended. - **The report:** Findings, repairs, outstanding defects and the next required inspection or service.
Refrigerant handling, electrical work, confined-space work and work at height require competent personnel, proper isolation and the permits your site requires. Follow manufacturer requirements and applicable regulations rather than this checklist wherever they differ.
## What good records look like
A useful record answers four questions at a glance:
1. What was checked, and by whom? 2. What did you find, in numbers where numbers exist? 3. What action was taken, and when? 4. What is still outstanding, and who owns it?
Keep entries in one place, dated and readable by the next shift. A record that only the person who wrote it can interpret is a record that fails at handover.
## If you sell chiller, AHU or HVAC services
Buyers compare firms on their websites before they call. Three things tend to decide it:
- **What you actually do:** say plainly whether you install, commission, service or repair, and on which equipment. - **Proof you can point to:** named project types, sectors or outcomes, described honestly. - **What happens next:** response times, coverage areas and how to request a site visit, stated near the top of the page.
## About this checklist and the free review